An electric concrete pump is a hydraulic concrete conveying equipment driven by three-phase electricity, specially designed for construction sites with a stable grid power supply. Compared with diesel-powered pumps, it has the advantages of low noise, zero emissions and low operating cost, and is the first choice for urban construction projects with strict environmental and noise requirements. This portable concrete pumping machine adopts a trailer-mounted design, which can be easily towed to different construction sites, with a maximum pumping height of 40 meters and a conveying efficiency of 10-20 cubic meters per hour, fully meeting the needs of medium and small construction projects.
Electric Concrete Pump Technical Specifications
| Model | YG-20 | YG-30 | YG-40 | YG-50 |
| Motor power | 22KW | 37KW | 45KW | 55kw |
| Maximum outlet pressure | 26mpa | 28mpa | 28mpa | |
| Maximum theoretical throughput | 16-18m³/h | 20-22m³/h | 35m³/h | |
| The maximum particle size of aggregate | ≤20mm | ≤30mm | ≤40mm | |
| Vertical conveying distance | 40m | 80m | 120m | 150m |
| Horizontal conveying distance | 80m | 140m | 2600m | 300m |
| Diameter of the conveying pipe | 80mm | φ80 (100) mm | φ100 (80) mm | Φ125/100mm |
| Whole machine weight | 1600kg | 2200kg | 2400kg | 2500kg |
| Dimensions | 3400x1200x1600mm | 3600x1500x1600mm | 4000x1500x1550mm | 4200*1700*1750mm |


Suitable Application Scenarios For Electric Concrete Pumps
You can give priority to choosing electric concrete pumping equipment in the following scenarios, which can bring you higher cost performance and construction efficiency:
Construction sites with stable three-phase power supply: If your construction site has stable grid power support, electric pumps have lower operating costs. The electricity cost per hour is only 1/3 of the diesel cost of the same power model, which can greatly reduce long-term use costs.
Urban construction and downtown projects: Urban areas usually have strict noise and environmental protection requirements. The operating noise of electric pumps is more than 20dB lower than that of diesel models, and there is no exhaust emission, which can avoid resident complaints and work stoppages caused by noise and environmental problems.
Long-term continuous construction projects: The electric drive system has a more stable power output, no speed fluctuation caused by engine operation, a lower failure rate during long-term continuous operation, and less daily maintenance work.
For remote construction sites without grid power, or projects that require frequent transfer between scattered sites, diesel pumps will be a more flexible choice. You can choose the most suitable power type according to your actual project conditions.


Electric Concrete Pumping Equipment Advantages
- Zero-emission and low-noise operation, fully meeting the environmental and noise requirements of urban construction
- Maximum vertical pumping height of 40 meters, horizontal pumping distance of 100 meters, meets the needs of most medium and small projects
- Conveying efficiency of 10-20 cubic meters per hour, stable output without fluctuation
- Trailer-mounted design, can be towed by ordinary vehicles, easy to transfer between different construction sites
- Simple operation, workers can master all operations after simple training, no professional technicians required
- Low maintenance cost, no regular replacement of engine filters and other consumables, daily maintenance only requires regular cleaning of pipelines.
- This portable concrete pumping machine also has built-in overload protection and anti-blocking pipe function, which greatly reduces the failure rate during construction.
5 Practical Operation & Maintenance Tips For Electric Concrete Pumps
- Wiring safety before operation: Always use standard three-phase power cables that match the power of the equipment, and ensure reliable grounding to avoid electric leakage and motor damage. Do not use too long or too thin cables to avoid a voltage drop affecting motor operation.
- Motor daily maintenance: Regularly clean the dust and debris on the surface of the motor to ensure good heat dissipation. Check the motor temperature during long-term operation, and stop the machine to cool down when the temperature exceeds 70℃.
- Hydraulic system maintenance: Operators should replace the hydraulic oil every six months for frequently operated equipment and adopt standard 46# anti-wear hydraulic oil to keep the system running steadily.
- Winter use tips: When using in a low-temperature environment, preheat the hydraulic system for 5-10 minutes before loading to avoid damage caused by too high oil viscosity.
- Long-term storage: When not in use for a long time, drain the remaining water in the pipeline to avoid freezing and rusting, and store the equipment in a dry and ventilated place; cover the motor with a dust cover.


Electric Concrete Pump Trailer For Sale
Our electric concrete pump combines stable performance, low noise and zero-emission design, perfectly matching the construction needs of projects with a stable power supply. If you are looking for a reliable electric concrete pump trailer for sale for your construction projects, contact us today to get detailed technical specifications and a customized quotation for your specific needs.